Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | Line Interactive |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Eaton 5PX Gen2 UPS | ||||||
Technical Specifications | 1000 | 1500 | 2200 | 3000 | ||
Rated power(VA/W) | 1000VA/1000W | 1500VA/1500W | 2200VA/2200W | 3000VA/3000W | ||
Model | RT2U (Tower/Rack 2U) | RT2U (Tower/Rack 2U) | RT2U & RT3U | RT2U & RT3U | ||
Electrical characteristics | ||||||
Technology | Online interactive high frequency(pure sine wave) | |||||
Mains input voltage range | 160V-294V(Adjustable to 150V-294V) | |||||
Mains input frequency range | 47 to 70Hz (50Hz system), 56.5 to 70Hz (60Hz system), 40Hz in low sensitivity mode. | |||||
Output voltage | 230V(+6/-10%) (Adjustable to 200V*/208V/220V/230V/240V), 50/60Hz +/- 0.1Hz (Auto-sensing) | |||||
Connections | ||||||
Input | 1 IEC C14 (10A) | 1 IEC C14 (10A) | 1 IEC C20 (16A) | 1 IEC C20 (16A) | ||
Output | 8 IEC C13 (10A) | 8 IEC C13 (10A) | 8 IEC C13 (10A) 2 IEC C19 (16A) |
8 IEC C13 (10A) 2 IEC C19 (16A) |
||
Remote control outlets | 2 groups 2 IEC C13(10A) | 1 group 2 IEC C13(10A); 1 group 2 IEC C13(10A)+1 IEC C19(16A) | ||||
Additional hot-swappable maintenance bypass module output sockets | 4 × FR/Schuko sockets or 3 × BS sockets or 6 × IEC 10A sockets or terminal blocks (Hardware version) | |||||
Additional Flex PDU output socket | 8 × FR/Schuko sockets or 6 × BS sockets or 12 × IEC 10A sockets | |||||
Battery | ||||||
Typical backup time(min)** | 300W | 500W | 800W | 1200W | 1800W | 2500W |
5PX 1000 | 30 | 17 | 8 | |||
5PX 1000+1EBM/+4EBM | 148/591 | 83/332 | 48/192 | |||
5PX 1500 | 44 | 24 | 13 | 7 | ||
5PX 1500+1EBM/+4EBM | 164/611 | 92/346 | 53/199 | 33/123 | ||
5PX 2200 | 50 | 28 | 16 | 9 | 4 | |
5PX 2200+1EBM/+4EBM | 242/958 | 138/551 | 80/319 | 49/197 | 30/121 | |
5PX 3000 | 68 | 39 | 23 | 13 | 7 | 4 |
5PX 3000+1EBM/+4EBM | 255/950 | 146/546 | 86/323 | 54/201 | 33/124 | 22/84 |
Battery management | ABM® and temperature compensated charging methods (User selectable), automatic battery testing, deep discharge protection, automatic identification of external battery compartment. | |||||
Interface | ||||||
Communication port | 1 USB port + 1 serial RS232 port + 1 remote on/off mini terminal + 1 remote power-off mini terminal + 1 output relay mini terminal. | |||||
Communication slots | 1 slot for Network M2, INDGW-M2 or Relay-MS cards. | |||||
Working conditions, standards and certifications | ||||||
Operating temperature | 0 to 40ºC | |||||
Noises | < 40 dBA at typical loads | |||||
Safety | IEC/EN 62040-1, UL1778, CSA22.2 | |||||
EMC performance | IEC/EN 62040-2, FCC Class B, CISPR22 class B | |||||
Authentication | CE/CB Report (TUV)/cTUVus/EAC/UKCA/Ukr/Cm | |||||
Size(W×D×H) /Weight | ||||||
UPS size(mm) | 438×448×85.5 | 438×448×85.5 | 438×603×85.5(RT2U) 438×483×129(RT3U) |
438×603×85.5(RT2U) 438×483×129(RT3U) |
||
UPS weight(kg) | 19.6 | 22.4 | 28.2(RT2U)/27.5(RT3U) | 31.7(RT2U)/31.1(RT3U) | ||
EBM size(mm) | 438×448×85.5 | 438×448×85.5 | 438×603×85.5(RT2U) 438×483×129(RT3U) |
438×603×85.5(RT2U) 438×483×129(RT3U) |
||
EBM weight(kg) | 27.8 | 27.8 | 40.4(RT2U)/39.7(RT3U) | 40.4(RT2U)/39.7(RT3U) | ||
Service & Support | ||||||
Warranty | 1 year | |||||
* 5% derating at 200V voltage; | ||||||
** Backup time is an estimate and may vary depending on device, configuration, battery aging, temperature, and other factors. |
Product model* | 1000 | 1500 | 2200 | 3000 |
UPS RT2U | 5PX1000IRT2UG2 | 5PX1500IRT2UG2 | 5PX2200IRT2UG2 | 5PX3000IRT2UG2 |
UPS RT2U with Network Card | 5PX1000IRTNG2 | 5PX1500IRTNG2 | 5PX2200IRTNG2 | 5PX3000IRTNG2 |
UPS RT3U | 5PX2200IRT3UG2 | 5PX3000IRT3UG2 | ||
EBM | 5PXEBM48RT2UG2 | 5PXEBM72RT2UG2(RT2U) 5PXEBM72RT3UG2(RT3U) |
||
2 m battery connection cable | EBMCBL48RT | EBMCBL72 | ||
*All 5PX UPS and EBM come with rack kit; | ||||
**Netpack version comes standard with network management card. |