Galaxy VX Technical Specs | 500 KW to 1500 KW UPS |
Topology | On-line double corversion with eConversion mode |
Nominsl Power (KVA | 500-1250 kW(1250 kW input/output cabinet) 500-1500 kW(1500 kW input/output cabinet) |
Technical Power Ratings | 500 kW,625 kW,750 kW,800 KW,1000 KW 1100 kW,1250 kW,1500 kW |
Parallel capability | Up to 4 units (N+1) |
Input | |
Rnctifior Type | GBT active rectifier |
Nominal Input Voltage | 380V/400V/415V/440V/480V 3-wire (3PH+PE)or4wire(3PH+PE+N) (600 V with optional external transformer) |
nput Voltage Range | +20%/-15% |
nput Connection | Single or dual feed |
nput Frequency | 50 or 60 Hz nominal (40-70 Hz) |
nput Current Total Harmonic Distortion (THDI) |
<3% @100%load |
nput Power Factor | >0.99 |
Walk-in | 0 to 300s(configurable) |
Short Circuit Withstand Rating |
100 kA |
Output | |
Inverter Type | 4 Level IGBT,high efficiency,transformerless |
Nominal Output Voltages | 380V/400V/415V/440V/480 V 3-wire (3PH+PE)or4wire (3PH+PE+N) (600 V with optional external transformer |
Load Power Factor | 0.7 leading to 0.5 lagging without UPS derating |
Valtage Regulatio | +/-1% |
Frequency Ragulation | 50/60Hz +/-0.1%(free running |
Overload in Norma Operation (at 40 ºC) |
Continuous up to 110%10 minutes up to 125% 1 minute up to 150% |
Overload in Bypass Operation (at 40°C) |
Continuous up to 110%(380V/400V/ 415V/440V) Continuous up to 125%(480 V) 1 minute up to 150%(all voltages) |
Output Voltage Distortion (THDU) |
<2%at 100%linear load; <3%at 100%nonlinear load |
Output Power Factor | 1.0 KVA =kW |
Eficiency details | |
Double conversion mode | Up to 96.5% |
eConversion mode | Up to 99% |
Energy storage parameters | |
Type | Lithium-ion,VRLA,Wet Call,Flywheel |
Nominal DC Bus Voltage | 480VDC |
Common battery string | Yos (VRLA only |
Galaxy VX Technical Specs | 500 KW to 1500 KW UPS |
Communication | |
Multilingual Graphics 1CD Displa |
Yes |
Compatibility with APC Communication cards |
AP9630 |
Communication Details | Modbus TCPAIP SNMP Email Modbus RS-485 (optional) |
Mechanical dimensions | |
1250 kW VO Cabinet (H xWx D) | |
500 kW | 77.6x94.4x35.4in(1970x2400x900 mm) |
625/750 kW | 77.6x118.1x35.4in(1970x3000x900 mm) |
800/1000 kW | 77.6x141.6x35.4in(1970x3600x900 mm |
1100/1250 kW | 77.6x165.2x35.4in(1970x4200x900 mm) |
1250 kW N+1 | 77.6x188.8x35.4in(1970x4800x900 mm) |
1500 kW VO Cabinet (H xWx D) | |
500kW | 77.6x126x35.4in(1970x3200x 900 mm |
750KW | 77.6x149.6x35.4in(1970x3800x 900 mm |
1000 kW | 77.6x173.2x35.4in(1970x4400x900 mm) |
1250 kW | 77.6x196.9x35.4in(1970x5000x900 mm) |
1500 kW | 77.6x220.5x35.4in(1970x5600x900 mm |
1500 kW N+1 | 77.6x245.1x35.4in(1970x6200x900 mm |
Standards and approvals | |
Performance and Safety | UL 17785th edition,cUL CE,IEC 62040-1 EC 62040-3 (VFI-SS-111) |
EMC Emissions | FCC 47 Part 15 EC 62040-2 |
Seismic | OSHPD BC 2012 |
Surge | ANSI 62.4/B3 |
P lewel (Ingress Protection) | IP20 |
Ervironment | |
Operating Temperature | 0-40°ºC(32-104 F)without derating |
Humidity | 0-95%noncondonsing |
Elevation /Altitude | 1000 m(3333 ft)100%load without derating |
Standard features | |
Soft Start,Walk-in Charger for Compatibility with Gensets |
Yes,Adaptative,Configurable 1 to 300s |
Cold Start Function (start without mains) |
Yes |
Emergency Stop (EPO) | No |
Frequency Converter | Yes |
Backleed Protection | Yes |
Smart Power Test (SpoT) | Yes |