Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
700 VA | 1000 VA | 1500 VA | 2000 VA | 3000 VA | |
Rating(A/W) | 700VA/630 KW | 1000VA/900 kW | 1500VA/1350kW | 2000VA/1800 kW | 3000VA/2700KW |
Format | Tower | Tower or Rack 2U | |||
Electrica charxteristics | |||||
Technology | On-ine double-corversion with Power FactorCorrection (PFC)system | ||||
Nemina voltage | 200/208/220/250/240V | ||||
INput voitage range | 90-276V wilhout deralinglup to 120-276V withPerating) | 700-276V without derating lp to 140-776V with derating) | |||
rput frequency range/THDI | 40-70Hz.50/6CHz autoselection.frequencyponverter mode | ||||
Connections | |||||
Inout | 1IEC C14(10A) | 1IEC C14(10A) | IEC C14(104) | IEC C14(10A) | IEC C14(16A) |
Qulpuls | 6IEC C13(10A)sockels | 6IEC C13(10A)sockels | 6IEC C13(10A)sockels | 8IEC C13(10A)sockels | 8IEC C13(10A)SOckels+ 1IEC C19(16A)SOCKET |
Switched Outlet Group | 2 outlet groups | ||||
Batteres | |||||
Typical backup times*(minutes))load | 300W | 500W | 800W | 200W | 800W |
9SX/00 | 4 | 15 | |||
9SX1000 | 24 | 14 | 7 | ||
9SX 1000+1EBMI+4 EBM | 90/320 | 56/200 | 33/120 | ||
SX1500 | 59 | 25 | 12 | 7 | |
SX1500+1EBM/-4 EBM | 42/520 | 85/510 | 50/179 | 31/115 | |
9SX 2000(Tower | 62 | 56 | 22 | 3 | 7 |
9SX 2000(Tawcr)-1EBMI-4 EBM | 2801050 | h651620 | 00/390 | 65/250 | 40160 |
9SX 2000(Rack) | 42 | 25 | 4 | B | 45 |
9SX 2000(Rack)+1EBW+4 EBM | 0 | 120/480 | 72/270 | 45/175 | 30/118 |
9SX 3000 (Tower) | 78 | 45 | 29 | 7 | 10 |
9SX 3000(Tewer)*1 EBM/+4 EBM | 290/1100 | 0 | 108/421 | 68/255 | 45/68 |
95×3000IRack) | 57 | 33 | 20 | 2 | 7 |
9SX 5000(RDck)+1FRM/+4FRM | 220/870 | h25490 | 771280 | 50/1B0 | 32/121 |
Battcry mnogcment | ABM® and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic | ||||
Communication | |||||
Communicat on ports | 1 USB port + 1 serial RS232 port + 1 mini-terminal block for Remote Power Off + 1 mini-terminal block for Output relay | ||||
Cormmuical on skot | 1 slot for Network-M2, Network-MS, ModBus-MS or Relay-MS cards | ||||
Operating conditions,standards andpprowns | |||||
Dveratrg temperatue | 0to 40ºC | ||||
Typcal nose le | 40dB | 41dB | 43dB | 45d8 | 45dB |
Safety | IEC/EN 62040-1, UL 1778, CSA 22.2 | ||||
EMC | IEC/EN 62040 -2 , FCC Class B, CISPR22 Class B | ||||
Approvas &making | CE /CB report (TUV) / cULus / EAC / RCM / BIS | ||||
Dimensicns Hx wk Din mm/Weignt | |||||
UPS | 252x160x357111.5kg | Tower: 252x160x387/14.8kg | Tower: 252x160x437/18.5kg | Tower: 346x214x412/33.3kg | Tower: 346x214x412/33.4kg |
EBM | Tower: 252x160x387/19kg Rack: 86.5x438x438/22.2kg |
Tower: 252x160x387/24.5kg | Tower: 346x214x412/48.7kg | Tower: 346x214x412/48.7kg | |
Cuslomer service and support | |||||
NntantY | 2yeors | ||||
* Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc. | |||||
Parts nmoc | 9SX 700 VA | 95×1000 VA | 9SX 1500 VA | 9SX 2000 VA | 9SX 5000 VA |
UPS Tower | 95X10001 | 95X15001 | 9SX20001 | 9SX50001 | |
UPS Rack 2U | 95×100UR | 9SX1500R | 9SX2000R | 9SX5000R | |
EBW Tower | 9SXEBM56T | 95XEBM4BT | 7SXEBM96T | 95XEBM96T | |
EBM Rack 2U | 9SXEBM36R | 9SXEBM4BR | 9SXEBM72R | 9SXEBM72R | |
2m battery connection cable (Tower only) | EBMCBL36T | EBMCBL48T | EBMCBL96T | EBNCBL96T |