Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Easy UPS 3M technical specifications | ||||||
Rated Power(KVA/kW) | 60/60 | 80/80 | 100/100 | 120/120 | 160/160 | 200/200 |
Normal AC supply input | ||||||
Input voltage (V) | 380/400/415 V (3-phase + Neutral + PE) | |||||
Frequency (Hz) | 40-70 Hz | |||||
Input power factor | >0.99 | |||||
THDI | <3%at full linear load | |||||
Input voltage range | 342 to 477 V at full load at 40°ºC** | |||||
Dual mains input | Yes (default:single mains input) | |||||
Output | ||||||
Nominal output voltage (V) | 3:3-380/400/415V | |||||
Efficiency:Double conversion mode |
Up to 95.5% | |||||
Efficiency:ECO mode | Up to 9g% | |||||
Overload capacity in normal operation |
125%for 10 minutes,150%for 1 minute* | |||||
Output voltage tolerance | +/-1% | |||||
Communication and management | ||||||
Communication interface | RS485,dry contacts,Ethernet (SNMP,Modbus,TCP/IP,BACnet) | |||||
Control panel | Five inch touchscreen LCD,status,and display console | |||||
Weights and dimensions | ||||||
UPS for external batteries unpackaged/shipping dimensions (H×W×D,mm) |
915×360×850mm/ 1140×475×965mm |
915×360×850mm/ 1140×475×965mm |
915×360×850mm/ 1140×475×965 mm |
1300×500×850mm/ 1500×625×975mm |
1300×500×850mm/ 1500×625×975mm |
1300×600×850mm/ 1500×725×975mm |
UPS with internal batteries unpackaged/shipping dimensions (HxWxD,mm) |
1970×600×1000mm/ 2102×750×1125mm |
1970×600×1000mm 2102×750×1125mm |
||||
UPS for external batteries unpackaged/shipping weights (kg) |
109/133 | 140/164 | 145/169 | 193/223 | 227257 | 304/338 |
UPS for internal batteries without batteries unpackaged/shipping weight (kg) |
311 (360) | 339(387) | ||||
Reoulatory | ||||||
Safety | IEC/EN 62040-1 | Performance | IEC62040-3 | |||
EMC/EMI/RFI | IEC 62040-2 | Environmenta | IEC 62040-4 | |||
Markings | CE TUV | |||||
Battery type | ||||||
Battery type | UPS with internal batteries:VRLA;UPS for external batteries:VRLA or Lithium-ion | |||||
Nominal DC Bus (100%load) | +/-216 to +/-300 | |||||
Charging power in %of output power (selectable) |
for external batteries:1-20% with interna batteries:1-16% |
for external batteries:1-30% with internal batteries:1-24% |
for external batteries:1-24% |
for external batteries:1-20% |
or external batteries:1-22.5% |
for external batteries:1-24% |
Environmental | ||||||
Operating temperature | 0 to 40ºC | |||||
Relative humidity Operating elevation |
0 to 95%non-condensing | |||||
0 to 1,500 m at 100%load | ||||||
Audible noise at 1 m from unit |
60-100 kVA:65 dBA at 100%load*;120-200 kVA:<70 dBA at 100%load* | |||||
Protection class | P20 (optional IP30,IP40,and IPX2 kits available) |