Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | On-line |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Nominal Ratings (kVA) | 30 | 40 | 60 | |
Rectifier Type | 6P | 6P | 6P | |
Input | ||||
Nominal input voltage | 380/400/415 Vac -wire plus ground | |||
Input voltage range | 323 to 478 Vac | |||
Nominal input frequency | 50/60 Hz | |||
Input frequency range | 45 to 55 Hz/55 to 65 Hz | |||
Output Capacity | ||||
Nominal output voltage | 380/400/415 Vac - 3 Phase with Neutral | |||
Output Power Factor | 0.9 | |||
Frequency | ||||
Voltage stability | ±1% (Steady state); ±5% (Transient state) | |||
Transient recovery time | 20 milliseconds to 1% | |||
Frequency stability | ±0.1% (Synchronized with internal clock); ±6% (max)(Synchronized with bypass) |
|||
Overload capability | 101 to 110%, 60 minutes; 111 to 125%, 10 minutes; 126 to 150%, 1 minute |
|||
Voltage distortion with linear load |
<1% | |||
Voltage distortion with 100% Non- linear load |
<5% | |||
Permissible load unbalance | 100% | |||
Non linear load capability | 100% | |||
Load handing capability without kVA derating | 0.5 lagging to 0.9 lagging | |||
Phase angle displacement accuracy |
100% balanced load ±1° | |||
100% unbalanced load ±1° | ||||
Dimensions and weight | ||||
Depth (mm) | 810 | |||
Width (mm) | 715 | |||
Height (mm) | 1250 | |||
General | ||||
General and safety requirements for UPS | IEC 62040-1-1 | |||
EMC requirements for UPS | IEC 62040-2 | |||
UPS Classification according to IEC 62040-3 | VFI-SS-111 | |||
*Conditions apply | ||||
*Specifications are subject to change without any prior notification. | ||||
*Specifications considering 400V nominal voltage. |
Nominal Ratings (kVA) | 80 | 120 | 160 | 200 | 300 | 400 | 500 | |
Rectifier Type | 6p | 6P | 6P | 6P | 6P | 6P | 12P | |
Input | ||||||||
Nominal input voltage | 380/400/415 Vac 4-wire plus ground | |||||||
Input voltage range | 323 to 478 Vac | |||||||
Nominal input frequency | 50/60 Hz | |||||||
Input frequency range | 45 to 55 Hz/55 to 65 Hz | |||||||
Input current distortion with linear load (with filter) |
3 to 10% with optional filter | |||||||
Power factor (with filter) | 0.88 to 0.97 with optional filter | |||||||
Output Capacity | ||||||||
Nominal output voltage | 380/400/415 Vac 4-wire plus ground | |||||||
Output Power Factor | 0.9 | |||||||
Frequency | ||||||||
Voltage stability | ±1% (Steady state); ±5% (Transient state) | |||||||
Transient recovery time | 20 milliseconds (max) | |||||||
Frequency stability | ±0.1% (Synchronized with internal clock); ±6% (max)(Synchronized with bypass) | |||||||
Overload capability | 101 to 110%, 60 minutes; 111 to 125%,10 minutes; 126 to 150%, 1 minute; | |||||||
Voltage distortion with linear load | <1% | |||||||
Voltage distortion with 100% Non- linear load | <5% | |||||||
Permissible load unbalance | 100% | |||||||
Non linear load capability | 100% | |||||||
Load handing capability without kVA derating | 0.5 lagging to 0.9 lagging | |||||||
Phase angle displacement accuracy | 100% balanced load | ±1° | ||||||
100% unbalanced load | ±1° | |||||||
Dimensions | ||||||||
Depth (mm) | 875 | 855 | ||||||
Width (mm) | 900 | 1250 | 1640 | 2280 | 2640 | |||
Height (mm) | 1900 | |||||||
General | ||||||||
General and safety requirements for UPS | IEC 62040-1 | |||||||
EMC requirements for UPS | IEC 62040-2 | |||||||
UPS Classification according to IEC 62040-3 | VFI-SS-11 | |||||||
*Conditions apply | ||||||||
*Specifications are subject to change without any prior notification. |