5P and 5PX specifcations |
5P Technical Specifications |
650 |
850 |
1150 |
1550 |
Rating (VA/W) |
650VA/420W |
850VA/600W |
1150VA/770W |
1550VA/1100W |
Format |
Tower or Rack 1U |
Tower or Rack 1U |
Tower or Rack 1U |
Tower or Rack 1U |
Connections |
|
Input |
1 IEC C14 (10A) |
|
|
|
Outputs Tower model |
4 IEC C13 (10A) |
6 IEC C13 (10A) |
8 IEC C13 (10A) |
8 IEC C13 (10A) |
Outputs Rack 1U model |
4 IEC C13 (10A) |
4 IEC C13 (10A) |
6 IEC C13 (10A) |
6 IEC C13 (10A) |
Switched Outlet Group |
2 outlet groups |
|
|
|
Batteries |
|
Typical backup times at 50 and 70% load¹ |
|
|
|
|
5P |
9/6 mn |
12/7 mn |
12/7 mn |
13/8 mn |
Dimensions H x W x D / Weight 5P |
|
Tower models |
230*150*345mm/7.8kg |
230*150*345mm/10.4kg |
230*150*345mm/11.1kg |
230*150*445mm/15.6kg |
Rack 1U models |
43.2(1U)*438*364mm/8.6kg |
43.2(1U)*438*509mm/13.8kg |
43.2(1U)*438*509mm/14.6kg |
43.2(1U)*438*554mm/19.4kg |
Parts Numbers 5P |
650 |
850 |
1150 |
1550 |
Tower |
5P650i |
5P850i |
5P1150i |
5P1550i |
Rack 1U |
5P650iR |
5P850iR |
5P1150iR |
5P1550iR |
|
5PX Technical Specifications |
1500 |
2200 |
3000 |
|
Rating (VA/W) |
1500VA/1350W |
2200VA/1980W |
3000VA/2700W |
|
Format |
RT2U (Tower/Rack 2U) |
RT2U (Tower/Rack 2U) |
RT2U and RT3U |
|
Connections |
|
Input |
1 IEC C14 (10A) |
1 IEC C20 (16A) |
1 IEC C20 (16A) |
|
Outputs |
8 IEC C13 (10A) |
8 IEC C13 (10A) + 1 IEC C19 (16A) |
8 IEC C13 (10A) + 1 IEC C19 (16A) |
|
Switched Outlet Group |
2 outlet groups |
|
|
|
Batteries |
|
Typical backup times at 50 and 70% load¹ |
|
|
|
|
5PX |
19/11 mn |
15/8 mn |
14/9 mn |
|
5PX + 1 EBM |
90/54 mn |
60/35 mn |
66/38 mn |
|
5PX + 4 EBM |
285/180 mn |
210/125 mn |
213/121 mn |
|
Dimensions H x W x D / Weight 5P |
|
UPS and EBM Dimensions |
441 x 522 x 86.2 (2U) mm |
441 x 522 x 86.2 (2U) mm |
441 x 647 x 86.2 (RT2U) mm |
|
|
441 x 497 x 130.7 (RT3U) mm |
|
UPS weight |
27.6kg |
28.5kg |
38.08 (RT2U) - 37.33 (RT3U) |
|
EBM weight |
32.8kg |
32.8kg |
46.39 (RT2U) - 44.26 (RT3U) |
|
Parts Numbers 5PX |
1500 |
1500 Netpack² |
2200 |
2200 Netpack² |
3000 (RT3U) |
3000 Netpack² (RT2U) |
UPS |
5PX1500iRT |
5PX1500iRTN |
5PX2200iRT |
5PX2200iRTN |
5PX3000iRT3U |
5PX3000iRTN |
EBM |
5PXEBM48RT |
5PXEBM48RT |
5PXEBM48RT |
5PXEBM48RT |
5PXEBM72RT3U |
5PXEBM72RT2U |
1 Runtimes are shown at 0.7 power factor. Backup times are approximate and may vary with equipment, configuration, battery age, temperature etc. |
2 Network Management Card included as standard in Netpack versions. |
|
5P & 5PX electrical characteristics |
|
Technology |
Line-Interactive High Frequency (Pure Sinewave, Booster + Fader) |
Input voltage and frequency ranges without using batteries |
160V-294V (adjustable to 150V-294V) 47 to 70Hz (50 Hz system), 56.5 to 70Hz (60 Hz system), 40Hz in low-sensitivity mode |
Output voltage and frequency |
230 V Adjustable to 200V / 208V / 220V / 230V / 240V), 50/60 Hz +/- 0.1 % (autosensing) |
Battery management |
ABM and temperature compensated charging method (user selectable), automatic battery test, deep discharge protection |
Communication |
|
Communication Ports |
1 USB port + 1 RS232 serial port and relay contacts (USB and RS232 ports cannot be used simultaneously), 1 mini-terminal block for remote ON/OFF and Remote Power Off |
Communication Slot |
1 slot for Network-MS card, ModBus-MS or Relay-MS cards |
Operating conditions, standards and approvals |
|
Operating temperature |
0 to 35°C for 5P 650/850/1150, 0 to 40°C for 5P 1550 and 5PX |
Noise level |
<40dB for 5P, <45db for 5PX 1500/2200, <50db for 5PX 3000 |
Safety |
IEC/EN 62040-1, UL 1778 |
EMC, Performance |
IEC/EN 62040-2, IEC/EN 62040-3 (performance) |
Approvals |
CE, CB report (TUV) |