MODEL | Winner Pro 1KR(L) | Winner Pro 2KR(L) | Winner Pro 3KR(L) | Winner Pro 6KR(L) | Winner Pro 10KR(L) | |||||||
PHASE | Single phase with groud | |||||||||||
CAPACITI | 1000VA/800W | 2000VA/1600W | 3000VA/2400W | 6000VA/4800W | 10000VA/8000W | |||||||
INPUT | ||||||||||||
Nominal Voltage | 110/115/120/127VAC or 208/220/230/240VAC | 208/220/230/240VAC | ||||||||||
Input Voltage Range | 55-145 VAC or110-300 VAC at 50%load 85-140 VAC or 160-280 VAC at 100%load |
110-300 VAC±3%at 50%Load 176-300 VAC±3%at 100%Load |
||||||||||
Frequency Range | 40Hz ~70 Hz | 46Hz~54 Hz or 56Hz~64 Hz | ||||||||||
Power Factor | ≥0.99 @Nominal Voltage (100%load) | |||||||||||
OUTPUT | ||||||||||||
Output Voltage | 110/115/120/127VAC or 208/220/230/240VAC | 208/220/230/240VAC | ||||||||||
Voltage Regulation | ±1% | ±1% | ||||||||||
Frequency Range (Synchronized Range) | 47~53 Hz or 57~63 Hz | 46Hz~54 Hz or 56Hz~64 Hz | ||||||||||
Frequency Range (Batt.Mode) | 50 Hz±0.25 Hzor60Hz±0.3 Hz | 50 Hz±0.1 Hzor 60 Hz±0.1 Hz | ||||||||||
Current Crest Ratio | 3:1 | |||||||||||
Harmonic Distortion | ≤3%THD (Linear Load), ≤6%THD (Non-linear Load) |
≤3%THD (Linear Load), ≤5%THD (Non-linear Load) |
||||||||||
Transfer Time |
AC Mode to Battery Mode | Zero | 0 ms | |||||||||
Inverter to Bypass | 4 ms (Typical) | 0 ms | ||||||||||
Waveform(Batt.Mode) | Pure Sinewave | |||||||||||
EFFICIENCY | ||||||||||||
AC Mode | 88% | 89% | 90% | 92% | 93% | |||||||
Battery Mode | 83% | 87% | 88% | 90% | 91% | |||||||
BATTERY | ||||||||||||
Standard Model |
Battery Type | 12V/9AH | 12V/9AH | 12V/9AH | 12 V19 AH | |||||||
Numbers | 2 | 4 | 6 | 16 | 20 | 16 | 20 | |||||
Typical Recharge Time | 4 hours recover to 90%capacity | 9 hours recover to 90%capacity | ||||||||||
Charging Current | 1.0 A | 1A/2A(Adjustable) | ||||||||||
Charging Voltage | 27.4VDC±1% | 54.7 VDC±1% | 82.1 VDC±1% | 218.4VDC ±1% |
273 VDC ±1% |
218.4VDC ±1% |
273 VDC ±1% |
|||||
Long-run Model |
Battery Type | Depending on the capacity of external batteries | De pending on applications | |||||||||
Numbers | 2 | 3 | 4 | 6 | 8 | 6 | 8 | 16-20 pcs(Adjustable) | ||||
Charging Current (max.) | 1.0A/2.0A/4.0A/6.0 A | 1A/2A/4A/6A(Adjustable, 6A is only available for 16pcs batteries) |
||||||||||
Charging Voltage | 27.4VDC± 1% |
41.0VDC± 1% |
54.7 VDC ±1% |
82.1 VDC ±1% |
109.4VDC ±1% |
82.1 VDC ±1% |
109.4VDC ±1% |
218.4VDC±1%(Based on 16pcs batteries) | ||||
INDICATORS | ||||||||||||
LCD Pane | UPS status,Load level,Battery level,Input/Output voltage,Discharge timer,and Fault conditions | |||||||||||
ALARM | ||||||||||||
Battery Mode | Sounding every 4 seconds | |||||||||||
Low Battery | Sounding every second | |||||||||||
Overload | Sounding twice every second | |||||||||||
Fault | Continuously sounding | |||||||||||
PHYSICAL | ||||||||||||
Standard Model |
Dimension,DxWxH(mm) | 310x438x88 [2U] | 410x438x88 [2U] | 630x438x88 [2U] | UPS Unit 530x438x88 [2U] Battery Pack 888x438x88 [2U] |
UPS Unit: 530x438x88 [2U] Battery Pack: 580x438x133 [3U] |
UPS Unit 580x438x133[3U] Battery Pack: 580x438x133 [3U |
|||||
Net Weight (kgs) | 12 | 19 | 29.3 | UPS Unt 15 Battery Pack: 48 |
UPS Unit 15 Battery Pack: 61 |
uPS Unt 18 Battery Pack: 51 |
UPS Unit 18 Battery Pack: 61 |
|||||
Long-run Model* |
Dimension,DxWxH(mm) | 310x438x88 [2U] | 410x438x88 [2U] | 530x438x88 [2U] | 580x438x133[3U] | |||||||
Net Weight (kgs) | 9 | 12 | 14.2 | 15 | 18 | |||||||
ENVIRONMENT | ||||||||||||
Humidity | 20-90 %RH @0-40ºC(non-condensing) | 0-95 %RH @0-40°ºC(non-condensing) | ||||||||||
Noise Level | Less than 50dB @1 Meter | Less than 55dB @1 Meter | Less than 58dB @1 Meter | |||||||||
MANAGEMENT | ||||||||||||
Smart RS-232/USB | Supports Windows Family,Linux and MAC | |||||||||||
Optional SNMP | Power management from SNMP manager and web browser |