Liebert EXL Specifications | ||||||
TECHNICAL SPECIFICATIONS | ||||||
UPS Rating kVA) 300 400 500 600 800 1000 1200 | ||||||
INPUT | ||||||
Nominal mains input voltage / voltage range* (V) | 400 (200 to 460), 3Ph or 3Ph + N | |||||
Nominal bypass input voltage / voltage range* (V) | 50±10%(60 selectable) | |||||
Nominal frequency / frequency tolerance (Hz) | ≥0.99 | |||||
Nominal bypass input voltage / voltage range* (V) | 400 (380/415 selectable), 3Ph or 3Ph + N | |||||
Nominal frequency / frequency tolerance (Hz) | 50±10%(60 selectable) | |||||
Input Power Factor | ≥ 0.99 | |||||
Input current distortion (THDi) (%) | ≤3 | |||||
OUTPUT | ||||||
Nominal output voltage (V) | 400 (380/415 selectable), 3Ph or 3Ph + N | |||||
Nominal output frequency (Hz) | 50 (60 selectable) | |||||
Output voltage stability by load variation 0-100% (%) static dynamic |
±1 | |||||
Complies with IEC/EN 62040-3, Class 1 | ||||||
Output frequency stability synchronized with bypass mains synchronized with internal clock (%) |
±2 (2, 3, 4, 5 selectable) | |||||
±0.1 | ||||||
Inverter Overload Capacity* | 110% continuous, 125% for 10mins, 150% for 1min | |||||
Output PF* | up to 1 | |||||
Inverter Overload Capacity* | 110% continuous, 125% for 10mins, 150% for 1min | |||||
Output PF* | up to 1 | |||||
Load crest factor handled without derating the ups (Ipk/Irms) | 3:01 | |||||
Compatibility with loads | Any power factor (leading or lagging) up to 1 | |||||
BATTERY | ||||||
Permissible battery voltage range (V) | 396 to 700 | |||||
Float voltage for VRLA @ 20 °C (V/cell) | 2,27 | |||||
End cell voltage for VRLA (V/cell) | 1.65 | |||||
Float Voltage stability in steady state condition (%) | ≤1 | |||||
DC ripple voltage without battery (%) | ≤1 | |||||
Battery Switch | Not included | |||||
BAPASS | ||||||
Manual Maintenance Bypass | 50 (60 selectable) | Included 100-500 kW | Not included 600-1200 kW | |||
CENERAL AND SYSTEM DATA | ||||||
Classification according to IEC/EN 62040-3 | VFI-SS-111 | |||||
Operating Temperature (°C) | 0-40 | |||||
Maximum relative humidity @ 20 °C (non condensing) (%) | up to 95 | |||||
Protection degree with open doors | IP 20 | |||||
Frame colour (RAL scale) | 7021 | |||||
Noise @ 1 metre as per ISO 3746 (dBA ± 2dBA) | 69 | 71 | 76 | 78 | ||
6 5 dBA @partial load | 70 dBA @partial load | 72 dBA @partial load | ||||
Parallel configuration | Parallel configuration | |||||
Access | Front and Top (no rear access required) | |||||
AC/AC efficiency: VFI according to IEC/EN 62040 definition (%) VFD according to IEC/EN 62040 definition (%) |
up to 97% up to 99% |
|||||
DIMAENSION AND WEIGHT | ||||||
Height (mm) | 1950 | |||||
Width (mm) | 1000 | 1250 | 2000 | 2650Net Weight (kg) | ||
Net Weight (kg) | 900 | |||||
Net Weight (kg) | 725 | 990 | 1550 | 2275 |